- Put the bike in the riding position.
- Start the device – by turning the crank twice in reverse.
- Make sure the battery in the meter has at least 10% life.
- Set the left crank arm vertically with the pedal down (6 o’clock) and make sure that no object touches the left arm. The pedal must be screwed to the left arm.
- Pair the bike computer with the power meter by entering the ID number located on the left crank or on the package in the ANT+ options.
- Start the ZERO OFFSET calibration function on the bicycle computer.
- After a while, you will see a message indicating the completion of the calibration and the value of the calibration process, which should be 1010. This process can take up to several tens of seconds. If the value deviates from the specified value, please contact us.
After the calibration process, the device is ready to go.
Comments
Calibration should be carried out relatively often, especially after a change in weather conditions – this will ensure correct POWERCRANK power meter readings. Calibration should be carried out every time the device is disassembled and assembled, as well as when the batteries are replaced.